Aquafuse Automatic Control Box Non Pressure Drainage Systems 230 Volts
Aquafuse AF 315 Automatic Control Box for Non Pressure Drainage Systems 230 Volt Supply
-
Available for use with 230v primary supply voltages
-
230v primary supply model contains step up transformer
-
Automatic set up prior to fusion
-
Power & constant current control circuit
-
Not for use with conventional 40v electrofusion fittings
-
Does not have historical fusion memory facility
-
Enclosure protected by steel frame
-
Fusion times set by automatic recognition of secondary power chords
-
Also available in 110v (see product options)
Secondary Power Cords - Sold Separately for various fitting manufacturers and various sizes too.
Please see the list below for more details:-
Code No. |
Description
|
Used for
|
01-01-055 |
Constant Current - Black Secondary Power Chord
4444
|
Coes fittings 200-315mm
with fusion times 100,150 & 200
seconds @20°C
|
01-01-057
|
Power Control - Yellow Secondary Power Chord
4444
|
Akatherm, Coes, Wavisolo, Valsir,
Gerberit with fusion times 80 seconds
@20°C
|
01-01-056
|
Power Control - Blue Secondary Power Chord
4444
|
Akatherm fittings 200-315mm
For Wavisolo fittings 200-315mm
For Valsir fittings 200-315mm
With fusion times 420 seconds @ 20°C
|
01-01-059 |
Power Control - Red Secondary Power Chord
1111
|
Gerberit fittings 200-315mm
with fusion time 600 seconds @ 20°C
|
01-01-058 |
Power Control - Green secondary power chord
4444
|
Wavisolo fittings 40-160mm
With fusion times 75 seconds @ 20°C
& 110 seconds @ 20° (larger fittings)
|
Important: All times given above are nominal.